Current / Voltage Control
The main task of rectifiers, plating process to provide electrical energy needs. Process according to their energy requirement may be in the form of constant voltage or constant current. MRS, rectifiers are designed to meet both needs and appropriate solutions for different needs can be ensured. Plating process to be captured rectifier current determines the magnitude of the material covered in the bathroom. If the same coating increases the amount of material needed for the flow will increase. Basic load factor is determined according to the load for the rectifier current and voltage values. Bath system materials, conductive cables and bus bars, fasteners, an electrical circuit. Rectifier connected to the load resistance is connected to this system will generate a total of Inverters. The larger the load resistance to this movement and will reduce the transition so difficult. Current flow of a particular need for devices that have a larger output voltage. The smaller the flow resistance for easier transition to a low voltage will be enough. Increase the amount of resistance will reduce the pool of material. Therefore, more current will attract the same voltage. However, poor contact with the ports, a small selection of conductor cross-section and so on. resistance increases and decreases in value due to current conditions can be withdrawn. One of the problems frequently encountered alınamamasıdır desired current density. For example, the total surface 4A 500dm2 / dm2'lik be coated with an intensity. In this case, we need a rectifier 4x500 = 2000A. However, this information alone is not sufficient for the selection of rectifier. In this case, you must ask the following question. 500dm2 parts with a surface area, how many volts the current draw with the tension? The answer to this question will give us an idea of what the rectifier output voltage. For example, aluminum anodizing process to the level of 11-12V rectifier current is almost unbearable at all, while the value of the then current value of 12V rises very quickly. As a result, the charger voltage, the material coated with the chemical activation voltage and rectifier resistances between the segments that form depends on the path. For processes that require a constant voltage, the charger output voltage is set to the desired value. Output current is set to be the largest value. Such a rectifier is run by setting the output voltage set value and fixed income. This stabilization, as long as does not exceed the current drawn rectifier currents in the upper current limit will continue as an independent. Of the parts depends on the load current drawn completely into the bathroom. For example, the 5V voltage may also hanging pieces 200A at 2000A. Rectifier within the limits for how many amps as long as it was taken in a flow will not be significant. Each condition Sagas 5V voltage. Rectifier can give up to 2000A and 2500A components have attracted consider the value of 5V. In this case, is engaged in protection and output current of rectifier voltage decreases as the level does not exceed 2000A'i. In this case, the output voltage is taken at the level of 4V. 5V output voltage drops automatically when the current value of the captured shock. Constant current output current under Require set to the value of the requested processes. The output voltage is set to the allowable maximum value. Such a study, the output current of rectifier output voltage increases until it reaches the desired value. The increase in value has been reached under Require stops. During the study the warming of parts, motion, etc. in the bathroom. reasons, if a change in load current of rectifier automatically keep the desired value.Rectifier output voltage drops gradually increasing the current drawn tries to meet this fall. Rectifier output voltage reaches the upper limit, however, could not increase the upper limit is now worth more voltage is fixed. Quite normal in this situation there is a capacity to stream some time in the direction of the desired rectifier misinterpreted.However, the value of rectifier voltage applied to the bathroom, but this value has reached the border even if the value of the load current do not attract sufficient. Lack of rectifier output current error is not such a case, the output voltage should be selected or a low conductivity is low in the bath system. Rectifier voltage value should be the job of the bath to ensure good contact and the chemical cleaning system of ports to increase the acidic property. MRS offers the opportunity to both control as a standard in the rectifiers. The same device can work with both current and constant voltage. Rectifier, according to adjustments made by the operator will operate automatically sets the method.
|